MS-200™

The MS-200™ panel is a fully crimped Standing Seam roof that is perfect for low slope roofs in any environment. The butyl injected seam prevents water from entering the system. Giving you a worry free roof for a lifetime. The system is a strong, durable, versatile, and perfect for long length roofs panels.

Features & Benefits

  • 12″, 14″, 16″ and 18″ options available
  • 24 and 22 Tru-Gauge™ and .032″ and .040″ Aluminum
  • Zinc Coil (inquire for thickness)
  • Floating clip system: allows for expansion/contraction of panels in longer lengths
  • 2″ vertical rib, factory notching available
  • ½:12 minimum pitch recommended (for lower pitches, please inquire)
  • On-site roll forming available for longer panels
  • Factory injected Butyl sealant available
  • Concealed fasteners: fasteners cannot leak
  • Weathertightness warranty available (Contact TMP representative for details)
  • MS-200™ FM Approvals Class: 4471
  • OverEZee retro-fit system available
  • Panel options: Striations, Accent Ribs, Flat Pan
  • Manufactured in Salem OR, Riverside CA & Sacramento CA

Material Specifications

  • 26 gauge Kynar 500® Painted Steel .019″ (thickness prior to painting) G-90 Galvanized or Zincalume® AZ-50
  • 24 gauge Kynar 500® Painted Steel .0236″ (thickness prior to painting) G-90 Galvanized or Zincalume® AZ-50
  • 26, 24 & 22 gauge bare Zincalume® Plus AZ-55 (no finish warranty  – 25 year perforation warranty)
  • 22 gauge Kynar 500® Painted Steel .029″ (thickness prior to painting) G-90 Galvanized or Zincalume® AZ-50
  • .032″ Kynar 500® Painted Aluminum
  • 16 and 20 ounce Copper (please inquire)
  • Kynar 500® and substrate testing data available (see website)
  • “Oil Canning” is an inherent characteristic of roof and wall products, and not a defect, which is not a cause for panel rejection

Testing

  • UL Construction No. 90, 176, 180, 238, 238A, 238B, 238C, 312, 335, 403, 435, 435 A, 437, 449, 451, 487, 506, 506A, 506B, 576, 577, 583, 608 & 610
  • UL 580 Class 90 – Wind Uplift
  • UL 790 Class A (ASTM E108) – Fire rated
  • UL 2218 Class 4 – Impact (hail) rated
  • FM Class 4471 – 1-75/120 wind uplift, Class A fire spread, severe hail & foot traffic
  • ASTM E1680 – Air Infiltration (roof)
  • ASTM E1646 – Water Infiltration (roof)
  • ASTM E1592 – Structural uniform static air pressure
  • ASTM E331 – Water Infiltration (wall)
  • ASTM E283- Air Infiltration (wall)
  • ASTM A653/A924 – G90 Galvanized
  • ASTM A792 – Zincalume/Galvalume AZ-50/55
  • ASTM B209 – Aluminum Substrate
  • ASTM E2140 – Standard Test Method for Water Penetration (full immersion)
  • ASTM E1514 – Standard for Structural Standing steel roof panels systems

Finishes

  • 21 Standard Colors, 5 Metallic Colors and 4 Specialized Colors
  • Vintage® has a color range that can vary from batch-to-batch and have directional variations
  • Rusteel Plus™ has no metallic coating, is unpainted and has no warranty
  • Kynar 500® Paint System-the ultimate in exterior durability and color retention
  • “Cool” color pigments are specially designed to reflect infrared light, reducing heat gain to dwelling, and conform with ENERGY STAR® criteria
  • Superior quality, two-coat, 70% resin finish, applied at a 1 mil. thickness
  • 40-year residential paint warranty
  • 20 and 30 year commercial paint warranty: Contact TMP for warranty specifications

   DI SEAMER RENTAL: click here

DI SEAMER Standard Rental Guidelines: click here 

• 180 degree seams are not considered an architectural detail. The detail improves the weather tightness and wind uplift capabilities of the panel system, but will show stress and waviness in the seam. The detail is recommended for slopes less than 3/12, roof areas not easily viewed from the ground, and for high wind areas. For additional information, contact a TMP representative and DI Seamers for support and information about the proper use of seaming tools.

Request More Information